Note: This methord is only worked on V1.0 III version.
Required Materials:
- 1x P1 HD VRX Nano V1.0.3 (complete set)
- 1x Jumper wire
Procedure:
-
Use the jumper wire to connect the 3 solder pads inside the red box (shown in the image below).
Caution: Don't allow solder to bridge to adjacent pads.
-
After wiring:
Precautions when you using the internal power supply:
- After converting to goggle-side power supply, do not connect an external power source. (Using an external power source after the jumper connection may damage the glasses). (Beta Test version only).
- Low Voltage Alert must be disabled in the receiver settings. This will not affect normal operation. If left enabled, the device will beep with a low voltage warning.
- SKYZONE goggles require a corresponding firmware update.
How to Disable Low Voltage Alert:
-
Settings → Device → Low Battery Alert, and toggle the switch to off.
How to Update Firmware for SKYZONE Goggles:
-
Connect the goggles to your computer via a USB cable.
-
Simultaneously hold the left shuttle wheel button and press the power button to turn on the goggles.
-
A removable disk drive will appear on your computer.
-
Copy the following two files into the removable disk. The update is complete once the file transfer finishes.